Kompatible Dateitypen - compatible file types

Aus folgenden Dateitypen kann winlactat 4.6 (Edition CPET architect) und winlactat 5.x Daten einlesen um Reports zu generieren:

winlactat is compatible to the following file formats or devices:

Hersteller/Manufacturer Herstellersoftware (Dateityp)/Software (file type) Bemerkungen / Remarks Beispieldateien / Sample files (see remarks)
CORTEX Metasoft Studio 4.x (XML) BBB (s. Version 4.x) file 1
COSMED Fitmate (PS) Postscript file on USB Stick file 1
COSMED Fitmate (TXT) Export text file from Fitmate Nutrition & Exercise software
COSMED Nutrition & Exercise software (XLS) BBB file 1
COSMED OMNIA 1.3-1.6 (XLSX) BBB
FES ConceptII rowing ergometer (HL7) Only step test data (no BBB)
GANSHORN LF8 (text file) 10 sec interval, filename e.g LF8.txt or LFSport.txt file 1
TERRA SOFTWARE Athletics pro (*.TXT) Master data only file 1
ZAN Spire (text file) BBB, filename EXED*.dat
EKF/SENSLAB Lactate Scout (h/p/cosmos Sirius) Serial/USB/Bluetooth connection
EKF/SENSLAB Lactate Scout Assistant Software LSA File
EKF Biosen Line (S oder C) Serial or LAN connection, LAN/WLAN Serversoftware
DIAGLOBAL VARIO Photometer Serial or LAN connection, LAN/WLAN Serversoftware
LANGE/HACH LP20-Laktatphotometer Serial or LAN connection, LAN/WLAN Serversoftware
JÄGER LabManager 4.6 (XLO file) BBB, file extension .XLO
CAREFUSION/VIASYS (JÄGER) JLab 5.0 (text file) BBB, filename winlacexp.txt in folder "C:\Lab5\DB"
CAREFUSION/VIASYS (JÄGER) Sentry Suite (text file) BBB, filename winlacexp.txt
AEROLUTION Auswertung Excel Export (XLS) only contains step test data (no BBB)
GERATHERM / KATHARINA GANSHORN BlueCherry(e.g. Ergostik) (XML) BBB
INNOVISION INNOCOR text file (TXT) BBB
POLAR HRM file(*.hrm)
MICROSOFT Excel file 2003-2007 (XLS) Can contain step test data or BBB (Interpreter)
SCHILLER (GANSHORN) LF8 (text file) 10 sec interval, filename e.g LF8.txt or LFSport.txt file 1
TXT Text file(TXT) Can contain step test data or BBB (Interpreter)
H/P/COSMOS h/p/cosmos para control V5.0 export (PC5)
RBM Elektronik Automation GmbH Cyclus2 (c2d unpacked)
ERGONIZER Übernahme der Datenbank oder HL7 Einzeldateien/ Complete data base or single HL7 files
MEDTRONIK Lactware 4.0 Übernahme der Datenbank / Complete data base
THEDEX all THEDEX compatible products (only winlactat <=4.7) Person data
GDT Schnittstelle Order file all GDT compatible products (s. here) Person data
GDT Schnittstelle Export file all GDT compatible products (s. here) winlactat test data and results
HL7 Order file all HL7 compatible products (s. here) Person data file 1
HL7 Export file all HL7 compatible products (s. here) winlactat test data and results file 1

Erläuterungen / Remarks

BBB: breath-by-breath data (Atemzugdaten)

2): Nutzen Sie "Datei speichern unter..." um die Beispieldatei herunterzuladen.

Use "Save file as" to download the sample file.

Import durchführen / Importing files

So führen Sie einen Import durch.